Publication:
MANAGING THE RISK OF LEGIONELLA IN DRINKING WATER AERATION PROCESSES

dc.contributor.advisor Le Clech, Pierre
dc.contributor.advisor Leslie, Greg
dc.contributor.advisor MacIntyre, Raina
dc.contributor.author Yunana, Danladi
dc.date.accessioned 2022-10-26T01:28:15Z
dc.date.available 2022-10-26T01:28:15Z
dc.date.issued 2022
dc.date.submitted 2022-10-24T21:52:39Z
dc.description.abstract Experimental and probabilistic methods were used to assess the risk of exposure to Legionella sp from aerators used in groundwater treatment plants. Factors considered include an assessment of conditions conducive to Legionella growth, detachment and inhalation by operators; the use of coupon studies to understand temporal changes and biofilm formation; and modelling the risk of Legionella using iterative Bayesian networks (BNs). A survey of 13 groundwater treatment plants (GWTPs) aerators, including tray, open and semi-enclosed systems were identified to feature design and operational risk factors favouring elevated levels of nutrients, water stagnation, challenging water quality, aerosolisation, and inconsistent operation and maintenance. Based on these observations, design considerations for the next generation of safer aerators that can overcome identified Legionella risks factors were outlined. Analysis of 300 sampling events from the aerators over five years indicated an average of 7% increase in colony counts between the inlet and outlet, indicating growth of Legionella within the aerators. In total, 28% of all samples collected from aerator surfaces testing positive for Legionella. However, there was no correlation between the type of aerator and Legionella positivity. Coupons were placed in aerators to assess temporal changes in fouling developed after 6 weeks of operation. The biological activity per unit area (ATP/cm2) was higher for samples collected on the sprayed (vertically placed) coupons (277 ng ATP/cm2) compared with the submerged (horizontally laid) (73 ng ATP/cm2) coupons. Concentrations of dissolved organic carbon (DOC) in the biofilm formed on the coupons were statistically similar for the two tested conditions. Comparing fouling characteristics from the lab and full-scale coupons confirmed the impact of surface orientation and influent characteristics on biofilm formation. In terms of cleaning of the fouled surface, NaOCl at (concentration greater than 6%) was found to achieve 99.9% efficiency in biofilm inactivation. Oxalic acid (concentration greater than 1%) significantly removed inorganic materials like iron and manganese. Combining biocides and antiscalants was therefore recommended to efficiently address fouling challenges in aerators. A BN which considered risk of exposure due to growth and transmission was developed using a fishbone diagram and bowtie analysis. The initial iterative output BN model was elicited deterministically through expert weighted scoring process and discretisation approach and defined relative contributions of risk variables. The BN model also efficiently categorised and differentiated Legionella risk thresholds. A revised BN model conceptually mapped and estimated the causes and consequences of Legionella aerosolisation separately. The Legionella growth sub-model showed weak prediction accuracy with a negative kappa coefficient, signifying inconsistency in predicted and observed Legionella occurrence. The effect of water quality was further explored with a data-driven learning approach using diverse historical water quality records. The optimised BN model utilised the greedy thick thinning approach, complemented with domain knowledge, and achieved superior performance accuracy exceeding 90%. The results indicated that water temperature, free chlorine, season, and heterotrophic plate count can be utilised to track Legionella occurrence in water systems.
dc.identifier.uri http://hdl.handle.net/1959.4/100725
dc.language English
dc.language.iso en
dc.publisher UNSW, Sydney
dc.rights CC BY 4.0
dc.rights.uri https://creativecommons.org/licenses/by/4.0/
dc.subject.other Legionella
dc.subject.other opportunistic pathogen
dc.subject.other water treatment
dc.subject.other bayesian modelling
dc.subject.other risk assessment
dc.title MANAGING THE RISK OF LEGIONELLA IN DRINKING WATER AERATION PROCESSES
dc.type Thesis
dcterms.accessRights open access
dcterms.rightsHolder Yunana, Danladi
dspace.entity.type Publication
unsw.accessRights.uri https://purl.org/coar/access_right/c_abf2
unsw.date.workflow 2022-10-25
unsw.identifier.doi https://doi.org/10.26190/unsworks/24432
unsw.relation.faculty Engineering
unsw.relation.faculty Medicine & Health
unsw.relation.school School of Chemical Engineering
unsw.relation.school School of Chemical Engineering
unsw.relation.school The Kirby Institute
unsw.relation.school School of Chemical Engineering
unsw.subject.fieldofresearchcode 40 ENGINEERING
unsw.thesis.degreetype PhD Doctorate
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
public version.pdf
Size:
44.92 MB
Format:
application/pdf
Description:
Resource type