Collector current density and dust collection in wire-plate electrostatic precipitators

Download files
Access & Terms of Use
open access
Copyright: Yuen, Albert Wai Ling
Altmetric
Abstract
Even minimal improvements in particle collection efficiency of electrostatic precipitators significantly reduce dust emission from fossil-fuelled power stations and reduce pollution. Yet current designs rely on the Deutsch collection theory, which was developed for tubular precipitators and has been applied to wire-plate precipitators on the assumption that the inter-electrode electric fields at the same discharge distance in both were similar. Differences in geometry and associated collector electric fields and current density non-uniformity have not been taken into account, although the collector electric field and current density of the wire-plate precipitator are not uniform. And observations show that precipitated dust patterns and the distribution of collector current density are interrelated. Investigations revealed a simple square law relationship between the collector electric field and the collector current density in the space charge dominated coronas. Applying this relationship to the Deutsch collection theory led to a current-density-based collection formula that takes into account the non-uniform collector current density distribution. The current-density-based collection formula is then used to assess the impact of collector current density on collection efficiency, the results closely following published measurements. Applying the current-density-based collection formula to estimate the dust accumulation shows that most of the dust accumulates at collector locations facing the corona wires. The effect of the non-uniform precipitated dust layer on collection performance is assessed using the distributed corona impedance - the ratio of the inter-electrode voltage and the non-uniform collector current. Re-distribution of the collector current profile as dust builds up is also compatible with published measurements. Finally this is applied to optimize the wire-plate precipitator collection performance. This shows that optimal collection performance is obtained with the wire-wire spacing less than the wire-plate distance, once again confirming published experimental results. This is the first analytical approach to show better collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the standard industry practice since 1960.
Persistent link to this record
Link to Publisher Version
Link to Open Access Version
Additional Link
Author(s)
Yuen, Albert Wai Ling
Supervisor(s)
Creator(s)
Editor(s)
Translator(s)
Curator(s)
Designer(s)
Arranger(s)
Composer(s)
Recordist(s)
Conference Proceedings Editor(s)
Other Contributor(s)
Corporate/Industry Contributor(s)
Publication Year
2006
Resource Type
Thesis
Degree Type
PhD Doctorate
UNSW Faculty
Files
download whole.pdf 2.11 MB Adobe Portable Document Format
Related dataset(s)