An aid to the design of orifice plates according to ISO Code 5167

dc.contributor.author Fietz, T. R. en_US
dc.date.accessioned 2021-11-25T12:39:48Z
dc.date.available 2021-11-25T12:39:48Z
dc.date.issued 1988 en_US
dc.description.abstract Measurement of liquid flow rate by orifice plates, particularly water, according to ISO Code 5167 is discussed. Computer programs, design charts, tables and examples are given for determination of orifice plate diameter and estimation of flow rate, head loss, cavitation and uncertainty in measurements. en_US
dc.identifier.isbn 0858243636 en_US
dc.identifier.uri http://hdl.handle.net/1959.4/36185
dc.language English
dc.language.iso EN en_US
dc.publisher University of New South Wales - Water Research Laboratory en_US
dc.rights CC BY-NC-ND 3.0 en_US
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/3.0/au/ en_US
dc.source Legacy MARC en_US
dc.subject.other flow measurement en_US
dc.subject.other cavitation en_US
dc.subject.other orifice flow en_US
dc.subject.other pipe flow en_US
dc.subject.other errors en_US
dc.title An aid to the design of orifice plates according to ISO Code 5167 en_US
dc.type Report en
dcterms.accessRights metadata only access
dspace.entity.type Publication en_US
unsw.accessRights.uri http://purl.org/coar/access_right/c_14cb
unsw.description.notePublic Number of pages: 46pp en_US
unsw.publisher.place Sydney en_US
unsw.relation.faculty Engineering
unsw.relation.ispartofreportnumber 173 en_US
unsw.relation.originalPublicationAffiliation Fietz, T. R., Water Research Laboratory, UNSW en_US
Files
Resource type