Publication:
Test of 10-inch orifice plate and carrier tubes. May 1961.

dc.contributor.author Wood, I. R. en_US
dc.date.accessioned 2021-11-25T12:42:03Z
dc.date.available 2021-11-25T12:42:03Z
dc.date.issued 1961 en_US
dc.description.abstract Ten inch orifice plate tested for heads of 120 and 77 inches. Error in computed discharge was -0.5 %. Tests were incomplete. en_US
dc.identifier.uri http://hdl.handle.net/1959.4/36254
dc.language English
dc.language.iso EN en_US
dc.publisher University of New South Wales - Water Research Laboratory en_US
dc.rights CC BY-NC-ND 3.0 en_US
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/3.0/au/ en_US
dc.source Legacy MARC en_US
dc.source WRL Digitisation
dc.subject.other orifice flow en_US
dc.subject.other orifices en_US
dc.subject.other pipes en_US
dc.subject.other Bailey Meters and Controls (Aust) Pty. Ltd. en_US
dc.title Test of 10-inch orifice plate and carrier tubes. May 1961. en_US
dc.type Report en
dcterms.accessRights open access
dspace.entity.type Publication en_US
unsw.accessRights.uri https://purl.org/coar/access_right/c_abf2
unsw.identifier.doi https://doi.org/10.4225/53/578c3fc34aa9d en_US
unsw.relation.faculty Engineering
unsw.relation.ispartofreportnumber UNSW Water Research Laboratory Report No. 42 en_US
unsw.relation.originalPublicationAffiliation Wood, I. R., Water Research Laboratory, Faculty of Engineering, UNSW en_US
unsw.relation.school School of Civil and Environmental Engineering *