  • (1988) Fietz, T. R.
    Report
    Measurement of liquid flow rate by orifice plates, particularly water, according to ISO Code 5167 is discussed. Computer programs, design charts, tables and examples are given for determination of orifice plate diameter and estimation of flow rate, head loss, cavitation and uncertainty in measurements.